18
Gas sampling and gas conditioning technology 6-1.1.1-ME
Figure 9 Sectional drawing pump MP47
Parts and tools required:
Valve plates and structured diaphragm (see spare part list , chapter 20)
Always change valve plates, diaphragm and sealing rings at the same time.
Change the diaphragm and valve plates in the following sequence:
18.1 EXCHANGE OF THE DIAPHRAGM
Mark the position between housing A , diaphragm B and pressure plate C ;
Loosen the 4 hexagon screws H and remove the pressure plate C and the diaphragm head B ;
Unscrew the diaphragm K by hand out of the tapping hole of the rod L (counterclockwise);