Mc-techgroup ECS Operator's manual Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Mc-techgroup ECS Operator's manual. M&C TechGroup ECS Operator's manual User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Electric gas cooler series EC

Gas sampling and gas conditioning technology 3-4.1-ME Operating Manual Electric gas cooler series EC ® Version EC/ECS (from model nos.:

Strona 2

10 Gas sampling and gas conditioning technology 3-4.1-ME 9 DESCRIPTION Figure 2 shows the EC/ECS cooler unit with the optional universal units

Strona 3

11 Gas sampling and gas conditioning technology 3-4.1-ME The EC/ECS  is equally suitable for wall installation or mounting in a 19“-rack. The

Strona 4

12 Gas sampling and gas conditioning technology 3-4.1-ME 10 FUNCTION The M&C EC/ECS gas cooler is a compressor cooler with status alarm ca

Strona 5 - Head Office

13 Gas sampling and gas conditioning technology 3-4.1-ME 11 RECEPTION AND STORAGE The EC/ECS gas cooler is a complete pre-installed unit. 

Strona 6 - 4 WARRANTY

14 Gas sampling and gas conditioning technology 3-4.1-ME 13 SUPPLY CONNECTIONS 13.1 HOSE CONNECTIONS The hoses for the heat exchangers are la

Strona 7

15 Gas sampling and gas conditioning technology 3-4.1-ME Condensate removal is done by customer according to the type of operation with: - Au

Strona 8 - Collecting vessel

16 Gas sampling and gas conditioning technology 3-4.1-ME Figure 4 shows the electrical connections at the plastic housing behind the front pane

Strona 9 - glass:

17 Gas sampling and gas conditioning technology 3-4.1-ME Before model nos. 96... the pin configuration for power and alarm connection was as fo

Strona 10 - 9 DESCRIPTION

18 Gas sampling and gas conditioning technology 3-4.1-ME The following steps should be carried out before initial start-up:  Connect the coo

Strona 11

19 Gas sampling and gas conditioning technology 3-4.1-ME 15 CLOSING DOWN NOTE! The location for the cooler must remain frost-free, even when

Strona 12 - 10 FUNCTION

2 Gas sampling and gas conditioning technology 3-4.1-ME List of Contents

Strona 13 - 11 RECEPTION AND STORAGE

20 Gas sampling and gas conditioning technology 3-4.1-ME When using automatic condensate removal by means of peristaltic pumps, the hoses of th

Strona 14 - 13.1 HOSE CONNECTIONS

21 Gas sampling and gas conditioning technology 3-4.1-ME DANGER Dangerous voltage! It is necessary to take the pump off the mains before any

Strona 15 - 13.2 ELECTRICAL CONNECTIONS

22 Gas sampling and gas conditioning technology 3-4.1-ME NOTE! Only the usage of the original hose set guarantees a perfect function. Never l

Strona 16 - 250V DC, 2A, 50W

23 Gas sampling and gas conditioning technology 3-4.1-ME 17 TROUBLE SHOOTING Troubleshooting is made much easier by the LED function display.

Strona 17 - 14 START-UP

24 Gas sampling and gas conditioning technology 3-4.1-ME LED display Function error and status alarm Probable cause Checking / Correction °C &

Strona 18 - °C <

25 Gas sampling and gas conditioning technology 3-4.1-ME 18 EC AUTOMATIC CONTROL BOARD Figure 8 shows the arrangement of the EC automatic con

Strona 19 - 16 MAINTENANCE

26 Gas sampling and gas conditioning technology 3-4.1-ME 18.1 CONNECTING THE COOLING COMPRESSOR The cooling compressor is connected to the EC

Strona 20

27 Gas sampling and gas conditioning technology 3-4.1-ME 18.2 TEMPERATURE SETTING FOR THE EC/ECS COOLER The EC/ECS gas cooler is set at the f

Strona 21

28 Gas sampling and gas conditioning technology 3-4.1-ME 19 CHECKING THE TEMPERATURE SENSOR The EC/ECS cooler temperature sensor is a PT100 el

Strona 22 -  anticlockwise

29 Gas sampling and gas conditioning technology 3-4.1-ME 20 CHANGING THE COOLER AGGREGATE NOTE! Before removing the cooler aggregate disconne

Strona 23 - 17 TROUBLE SHOOTING

3 Gas sampling and gas conditioning technology 3-4.1-ME List of Illustrations Figure 1 Example of application of EC/ECS ...

Strona 24

30 Gas sampling and gas conditioning technology 3-4.1-ME For changing the cooler aggregate please carry out the following steps:  Remove the

Strona 25

31 Gas sampling and gas conditioning technology 3-4.1-ME 21 RETROFITTING A DIGITAL TEMPERATURE INDICATION 21.1 DATA FOR MOUNTING Display LCD

Strona 26 - Art.Nr.: KL0001

32 Gas sampling and gas conditioning technology 3-4.1-ME For mounting the display and the temperature sensor please notice the following:  L

Strona 27

33 Gas sampling and gas conditioning technology 3-4.1-ME 22 SPARE PARTS LIST Wear, tear and replacement part requirements depend on specific o

Strona 28

34 Gas sampling and gas conditioning technology 3-4.1-ME 23 APPENDIX  Sample output dew point (ambient temperature 20°C) depending on gas fl

Strona 29 - Top view

35 Gas sampling and gas conditioning technology 3-4.1-ME Sample output dew point (ambient temperature 20°C) depending on gas flow rate

Strona 30

36 Gas sampling and gas conditioning technology 3-4.1-ME Figure 16 Circuit diagram EC automatic control board

Strona 31 - 21.1 DATA FOR MOUNTING

37 Gas sampling and gas conditioning technology 3-4.1-ME Universaleinheit EC-FD2300-5.05.0 Figure 17 Wiring plan automatic condensate removal

Strona 32 - 21.3 ELECTRICAL CONNECTIONS

4 Gas sampling and gas conditioning technology 3-4.1-ME Dear customer, we have made up this operating manual in such a way th

Strona 33 - condensate out 3/8“ NPTi

5 Gas sampling and gas conditioning technology 3-4.1-ME Head Office M&C TechGroup Germany GmbH  Rehhecke 79  40885 Ratingen  Germany T

Strona 34 - 23 APPENDIX

6 Gas sampling and gas conditioning technology 3-4.1-ME 3 SAFETY INSTRUCTIONS Please take care of the following basic safety procedure

Strona 35

7 Gas sampling and gas conditioning technology 3-4.1-ME 5 USED TERMS AND SIGNAL INDICATIONS DANGER! This means that death, severe phys

Strona 36

8 Gas sampling and gas conditioning technology 3-4.1-ME 6 INTRODUCTION The patented M&C EC/ECS gas cooler unit is always to be

Strona 37 - 2300-5.05.0

9 Gas sampling and gas conditioning technology 3-4.1-ME 8 TECHNICAL DATA Sample outlet dew point range of adjustment: +2 °C ... +7 °C, fact

Komentarze do niniejszej Instrukcji

Brak uwag